Significance and Use 5.1 Components of implanted medical devices can release ions, which may lead to adverse biological effects if released in sufficient quantities. Therefore, it may be necessary to characterize the ion release behavior over time to verify that a medical device or device components, or both, will not pose an unacceptable risk to patients. Some examples of when time-dependent ion release testing should be considered include: 5.1.1 New materials, 5.1.2 New applications (for example, different in-vivo environments or new designs) that may degrade corrosion resistance, 5.1.3 Manufacturing processes that may lead to increased ion release susceptibility, 5.1.4 Results of other corrosion testing (for example, Test Methods F2129 and F3044) indicate high susceptibility to corrosion. 5.2 Forming and finishing steps used to create an implantable device may have significant effects on the ion release behavior of the material from which the device is fabricated. Preconditioning can impact the ion release behavior of implants; therefore, prior to testing, devices should be subjected to preconditioning that is appropriate to their application. A justification shall be provided if preconditioning is omitted. Additional information on preconditioning is found in Appendix X1. Substitute test articles (tubes, plates, wires, device subcomponents, etc.) may be used for testing with adequate justification, if all processing steps, including sterilization and preconditioning, are comparable to the finished device. 5.3 To accommodate the wide variety of device shapes and sizes likely to be encountered, various sizes and shapes of containers manufactured from various materials can be used. The container material choice should be justified. 5.4 Note that the test conditions described in this test method may not completely simulate those encountered in vivo (cells, proteins, mechanical loading, and other specifics of the in-vivo environment); however, the results of this testing conducted in simulated physiological solutions can provide useful data to estimate exposure as part of a risk assessment (for example, as per ISO 10993-17) or to compare different device materials, designs, or manufacturing processes.Scope 1.1 This test method assesses metal or other ions released from single-use, metallic, implantable medical devices, or components thereof, by exposing the device to solutions simulating the in-vivo environment and temperature in a container for a predetermined time frame with regular sampling at adequate intervals. Examples of device types that may be evaluated by this test method include, but are not limited to: cardiovascular devices, endovascular devices, and orthopedic implants. Devices which are to be partially implanted, but in long-term contact within the body (such as external fixation devices) may also be evaluated using this method. 1.2 This test method is used to assess devices or device components, or both, in their final form and finish, as they would be implanted. For modular implants, consideration should be given to individual testing of every part. 1.3 This test method covers the selection of specimens, specimen preparation, test environment, method of exposure, and method for evaluating the results to characterize ion release. Because of the variety of configurations and sizes of implants, a variety of specimen container configurations may be used. 1.4 This test method is not intended for ions only adsorbed onto the surface of the samples. 1.5 This test method does not apply to absorbable metallic implants (for example, magnesium-based stents, bone screws, etc.) that are intentionally designed to degrade in-vivo. 1.6 This test method does not cover the required subsequent chemical analysis, for example, by inductively coupled plasma mass spectrometry (ICP-MS), or the validation of the analytical instrumentation. 1.7 This test method does not cover the influence of dynamic loading and associated surface damage or wear on ion release. Ion release may change under dynamic loading conditions and wear. Additional testing may be required, depending on the application and outcome of this test method. 1.8 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.10 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

American National Standards Institute Inc.

Go to ASTM F3306 at ASTM.org

Add your thoughts about the standard.

5935 - Connectors, Electrical (4357) 8455 - Badges and Insignia (3093) 8010 - Paints, Dopes, Varnishes, and Related Products (2046) 6515 - Medical and Surgical Instruments, Equipment, and Supplies (1907) ISDF (1827) 4730 - Hose, Pipe, Tube, Lubrication, and Railing Fittings (1823) ISDA (1776) FACR (1647) 5960 - Electron Tubes and Associated Hardware (1630) 6145 - Wire and Cable, Electrical (1629) 6505 - Drugs and Biologicals (1343) 6625 - Electrical and Electronic Properties Measuring and Testing Instruments (1241) 6640 - Laboratory Equipment and Supplies (1187) 5120 - Hand Tools, Nonedged, Nonpowered (1124) 6810 - Chemicals (1114) MISC (1045) 5930 - Switches (1012) 5306 - Bolts (996) 5340 - Hardware, Commercial (953) 8305 - Textile Fabrics (910) 5310 - Nuts and Washers (864) 5950 - Coils and Transformers (856) 8140 - Ammunition and Nuclear Ordnance Boxes, Packages and Special Containers (797) 6520 - Dental Instruments, Equipment, and Supplies (790) ISDD (786) 5910 - Capacitors (783) 5305 - Screws (781) 9330 - Plastics Fabricated Materials (759) 5905 - Resistor (753) 6530 - Hospital Furniture, Equipment, Utensils, and Supplies (745) 5945 - Relays and Solenoids (733) 5961 - Semiconductor Devices and Associated Hardware (707) 6240 - Electric Lamps (662) 8415 - Clothing, Special Purpose (660) 5330 - Packing and Gasket Materials (583) SESS (581) ISDN (581) 5940 - Lugs, Terminals, and Terminal Strips (564) 8030 - Preservative and Sealing Compounds (554) 4720 - Hose and Flexible Tubing (552) 1375 - Demolition Materials (549) 6610 - Flight Instruments (540) PACK (539) 8915 - Fruits and Vegetables (531) 1377 - Cartridge and Propellant Actuated Devices and Components (524)
Steel (908) GUN (640) (621) Demolition Materials (549) Cartridge and Propellant Actuated Devices and Components (524) Paint and Related Coating (456) Fuzes and Primers (454) Optical Sighting and Ranging Equipment (451) Medical Device and Implant (427) Building (414) Petroleum (378) Rockets, Rocket Ammunition and Rocket Components (368) Nonferrous Metal and Nonferrous Alloy (367) Ammunition, through 30mm (349) Fire Control Computing Sights and Devices (338) Aircraft Air Conditioning, Heating, and Pressurizing Equipment (334) Parachutes; Aerial Pick Up, Delivery, Recovery Systems; and Cargo Tie Down Equipment (324) Sports and Recreation (316) Land Mines (276) Nuclear Technology (274) Consumer Product Evaluation (267) Aircraft Hydraulic, Vacuum, and De-icing System Components (263) Bulk Explosives (261) Torpedos and Components, Inert (258) Plastic Pipe (248) Nondestructive Testing (246) Miscellaneous Aircraft Accessories and Components (231) Aerospace Material (225) Geotechnical Engineering (217) Miscellaneous Fire Control Equipment (216) Ammunition, over 30mm up to 75mm (208) Fire Control Radar Equipment, except Airborne (197) Ammunition, 75mm through 125mm (192) Bombs (192) Copper (192) Environmental Toxicology (187) Analytical Chemistry (180) Road and Paving (177) Pyrotechnics (175) Rubber (166) Electrical and Magnetic Conductor (162) Security System Pedestrian and Walkway Safety (157) Military Chemical Agents (156) Electronics (153) Specialized Test and Handling Equipment, Nuclear Ordnance (150)