Significance and Use

American National Standards Institute Inc.

4.1 Changes in temperature and humidity during shipping, storage or use can affect the visual appearance, mechanical integrity, or electrical functionality of switches. This practice simulates three different environments to which membrane switches may be exposed.

4.2 The three industry-recognized switch categories based on performance levels are Level 1, Level 2, and Level 3 (see section 9.1).

4.3 Additionally, there may be custom requirements that vary by application, therefore, these requirements can be determined by customer and vendor agreement and be established as a Level 4.

4.4 This practice defines the duration of a single cycle. Multiple cycles may be appropriate depending on the requirements of the application.

Scope

1.1 This test method covers a procedure for temperature and humidity cycling of a membrane switch or printed electronic device.

1.2 This test method is performed to evaluate the properties of materials used in the construction of membrane switch or printed electronic assemblies as they are influenced by the absorption and diffusion of moisture and moisture vapor. This is an accelerated environmental test, accomplished by the continuous exposure of the test specimen to high relative humidity at an elevated temperature. Absorption of moisture by many materials results in swelling, which destroys their functional utility, causes loss of physical strength, and changes in other mechanical properties. Insulating materials which absorb moisture may suffer degradation of their electrical properties.

1.2.1 Physical changes:

1.2.1.1 Differential contraction or expansion rates or induced strain of dissimilar materials.

1.2.1.2 Cracking of surface coatings.

1.2.1.3 Leaking of sealed compartments.

1.2.1.4 Deformation or fracture of components.

1.2.2 Chemical changes:

1.2.2.1 Separation of constituents.

1.2.2.2 Failure of chemical agent protection.

1.2.3 Electrical changes:

1.2.3.1 Changes in electronic and electrical components.

1.2.3.2 Electronic or mechanical failures due to rapid water of condensate formation.

1.2.3.3 Excessive static electricity.

1.3 This test method is not intended to be a thermal shock procedure; a ramp rate between temperature extremes should not exceed 2°C/min.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Go to ASTM F1596 at ASTM.org

Add your thoughts about the standard.

5935 - Connectors, Electrical (4357) 8455 - Badges and Insignia (3093) 8010 - Paints, Dopes, Varnishes, and Related Products (2046) 6515 - Medical and Surgical Instruments, Equipment, and Supplies (1907) ISDF (1827) 4730 - Hose, Pipe, Tube, Lubrication, and Railing Fittings (1823) ISDA (1776) FACR (1647) 5960 - Electron Tubes and Associated Hardware (1630) 6145 - Wire and Cable, Electrical (1629) 6505 - Drugs and Biologicals (1343) 6625 - Electrical and Electronic Properties Measuring and Testing Instruments (1241) 6640 - Laboratory Equipment and Supplies (1187) 5120 - Hand Tools, Nonedged, Nonpowered (1124) 6810 - Chemicals (1114) MISC (1045) 5930 - Switches (1012) 5306 - Bolts (996) 5340 - Hardware, Commercial (953) 8305 - Textile Fabrics (910) 5310 - Nuts and Washers (864) 5950 - Coils and Transformers (856) 8140 - Ammunition and Nuclear Ordnance Boxes, Packages and Special Containers (797) 6520 - Dental Instruments, Equipment, and Supplies (790) ISDD (786) 5910 - Capacitors (783) 5305 - Screws (781) 9330 - Plastics Fabricated Materials (759) 5905 - Resistor (753) 6530 - Hospital Furniture, Equipment, Utensils, and Supplies (745) 5945 - Relays and Solenoids (733) 5961 - Semiconductor Devices and Associated Hardware (707) 6240 - Electric Lamps (662) 8415 - Clothing, Special Purpose (660) 5330 - Packing and Gasket Materials (583) SESS (581) ISDN (581) 5940 - Lugs, Terminals, and Terminal Strips (564) 8030 - Preservative and Sealing Compounds (554) 4720 - Hose and Flexible Tubing (552) 1375 - Demolition Materials (549) 6610 - Flight Instruments (540) PACK (539) 8915 - Fruits and Vegetables (531) 1377 - Cartridge and Propellant Actuated Devices and Components (524)
Steel (908) GUN (640) (621) Demolition Materials (549) Cartridge and Propellant Actuated Devices and Components (524) Paint and Related Coating (456) Fuzes and Primers (454) Optical Sighting and Ranging Equipment (451) Medical Device and Implant (427) Building (414) Petroleum (378) Rockets, Rocket Ammunition and Rocket Components (368) Nonferrous Metal and Nonferrous Alloy (367) Ammunition, through 30mm (349) Fire Control Computing Sights and Devices (338) Aircraft Air Conditioning, Heating, and Pressurizing Equipment (334) Parachutes; Aerial Pick Up, Delivery, Recovery Systems; and Cargo Tie Down Equipment (324) Sports and Recreation (316) Land Mines (276) Nuclear Technology (274) Consumer Product Evaluation (267) Aircraft Hydraulic, Vacuum, and De-icing System Components (263) Bulk Explosives (261) Torpedos and Components, Inert (258) Plastic Pipe (248) Nondestructive Testing (246) Miscellaneous Aircraft Accessories and Components (231) Aerospace Material (225) Geotechnical Engineering (217) Miscellaneous Fire Control Equipment (216) Ammunition, over 30mm up to 75mm (208) Fire Control Radar Equipment, except Airborne (197) Ammunition, 75mm through 125mm (192) Bombs (192) Copper (192) Environmental Toxicology (187) Analytical Chemistry (180) Road and Paving (177) Pyrotechnics (175) Rubber (166) Electrical and Magnetic Conductor (162) Security System Pedestrian and Walkway Safety (157) Military Chemical Agents (156) Electronics (153) Specialized Test and Handling Equipment, Nuclear Ordnance (150)