Significance and Use

American National Standards Institute Inc.

5.1 Under the assumptions of the model, the Thurstonian model approach to measuring the perceived difference between two samples (whether overall or for a specific attribute) is independent of the sensory method used to collect the data. Converting results obtained from different test methods to d’ values permits the assessment of relative differences among samples without requiring that the samples be compared to each other directly or that the same test methods be used for all pairs of samples.

5.2 Thurstonian scaling has been applied to:

5.2.1 Creating a historical database to track differences between production and reference samples over periods in which different test methods were used to measure the difference,

5.2.2 Comparing the relative sensitivities of different user groups and consumer segments,

5.2.3 Comparing trained panels that use different measuring techniques,

5.2.4 Comparing the relative sensitivities of consumers versus trained panels,

5.2.5 Comparing different methods of consumer testing (for example, CLT versus HUT, preference versus hedonic scales, etc.), and

5.2.6 Comparing different discrimination test methods.

Scope

1.1 This practice describes procedures to estimate Thurstonian discriminal distances (that is, d’ values) from data obtained on two samples. Procedures are presented for four forced-choice methods (that is, the triangle, the Duo-Trio, the 3-alternative-forced-choice (or 3-AFC) and the 2-AFC (also called the directional difference test)), the A/Not-A method, the Same-Different method, and for data obtained from ordered category scales. Procedures for estimating the variance of d’ are also presented. Thus, confidence intervals and statistical tests can be calculated for d’.

1.2 The procedures in this practice pertain only to the unidimensional, equal-variance model. Other, more complicated Thurstonian models, involving multiple dimensions and unequal variances exist but are not addressed in this practice. The procedure for forced-choice methods is limited to dichotomous responses. The procedure for the A/Not-A method assumes equal sample sizes for the two samples. The procedure for the Same-Different method assumes equal sample sizes for the matched and unmatched pairs of samples. For all methods, only unreplicated tests are considered. (Tests in which each assessor performs multiple (that is, replicated) evaluations require different analyses.)

1.3 Thurstonian scaling is a method for measuring the perceptual difference between two samples based on a probabilistic model for categorical choice decision making. The magnitude of the perceived difference, δ, can be estimated from the assessors’ categorical choices using the methods described in this practice. (See Appendix X3 for a more detailed description of Thurstonian scaling.)

1.4 In theory, the Thurstonian δ does not depend on the method used to measure the difference between two samples. As such, δ provides a common scale of measure for comparing samples measured under a variety of test conditions. For example, Thurstonian scaling can be used to compare products measured under different test conditions, to compare panels (trained, consumer or both) that have evaluated the same samples (using the same or different test methods) and to compare test methods on their ability to discriminate samples that exhibit a fixed sensory difference.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Go to ASTM E2262 at ASTM.org

Add your thoughts about the standard.

5935 - Connectors, Electrical (4357) 8455 - Badges and Insignia (3093) 8010 - Paints, Dopes, Varnishes, and Related Products (2046) 6515 - Medical and Surgical Instruments, Equipment, and Supplies (1907) ISDF (1827) 4730 - Hose, Pipe, Tube, Lubrication, and Railing Fittings (1823) ISDA (1776) FACR (1647) 5960 - Electron Tubes and Associated Hardware (1630) 6145 - Wire and Cable, Electrical (1629) 6505 - Drugs and Biologicals (1343) 6625 - Electrical and Electronic Properties Measuring and Testing Instruments (1241) 6640 - Laboratory Equipment and Supplies (1187) 5120 - Hand Tools, Nonedged, Nonpowered (1124) 6810 - Chemicals (1114) MISC (1045) 5930 - Switches (1012) 5306 - Bolts (996) 5340 - Hardware, Commercial (953) 8305 - Textile Fabrics (910) 5310 - Nuts and Washers (864) 5950 - Coils and Transformers (856) 8140 - Ammunition and Nuclear Ordnance Boxes, Packages and Special Containers (797) 6520 - Dental Instruments, Equipment, and Supplies (790) ISDD (786) 5910 - Capacitors (783) 5305 - Screws (781) 9330 - Plastics Fabricated Materials (759) 5905 - Resistor (753) 6530 - Hospital Furniture, Equipment, Utensils, and Supplies (745) 5945 - Relays and Solenoids (733) 5961 - Semiconductor Devices and Associated Hardware (707) 6240 - Electric Lamps (662) 8415 - Clothing, Special Purpose (660) 5330 - Packing and Gasket Materials (583) SESS (581) ISDN (581) 5940 - Lugs, Terminals, and Terminal Strips (564) 8030 - Preservative and Sealing Compounds (554) 4720 - Hose and Flexible Tubing (552) 1375 - Demolition Materials (549) 6610 - Flight Instruments (540) PACK (539) 8915 - Fruits and Vegetables (531) 1377 - Cartridge and Propellant Actuated Devices and Components (524)
Steel (908) GUN (640) (621) Demolition Materials (549) Cartridge and Propellant Actuated Devices and Components (524) Paint and Related Coating (456) Fuzes and Primers (454) Optical Sighting and Ranging Equipment (451) Medical Device and Implant (427) Building (414) Petroleum (378) Rockets, Rocket Ammunition and Rocket Components (368) Nonferrous Metal and Nonferrous Alloy (367) Ammunition, through 30mm (349) Fire Control Computing Sights and Devices (338) Aircraft Air Conditioning, Heating, and Pressurizing Equipment (334) Parachutes; Aerial Pick Up, Delivery, Recovery Systems; and Cargo Tie Down Equipment (324) Sports and Recreation (316) Land Mines (276) Nuclear Technology (274) Consumer Product Evaluation (267) Aircraft Hydraulic, Vacuum, and De-icing System Components (263) Bulk Explosives (261) Torpedos and Components, Inert (258) Plastic Pipe (248) Nondestructive Testing (246) Miscellaneous Aircraft Accessories and Components (231) Aerospace Material (225) Geotechnical Engineering (217) Miscellaneous Fire Control Equipment (216) Ammunition, over 30mm up to 75mm (208) Fire Control Radar Equipment, except Airborne (197) Ammunition, 75mm through 125mm (192) Bombs (192) Copper (192) Environmental Toxicology (187) Analytical Chemistry (180) Road and Paving (177) Pyrotechnics (175) Rubber (166) Electrical and Magnetic Conductor (162) Security System Pedestrian and Walkway Safety (157) Military Chemical Agents (156) Electronics (153) Specialized Test and Handling Equipment, Nuclear Ordnance (150)