Significance and Use 5.1 This test method measures the time to extrapolated onset of an exothermic reaction under constant temperature (isothermal) conditions for reactions which have an induction period, for example, those which are catalytic, autocatalytic, or accelerating in nature or which contain reaction inhibitors. 5.2 The RIT determined by this test method is an index measurement that is useful for comparing one material to another at the test temperature of interest and in the same apparatus type only. 5.3 This test method is a useful adjunct to dynamic thermal tests, such as Test Method E537, which are performed under conditions in which the sample temperature is increased continuously at constant rate. Results obtained under dynamic test conditions may result in higher estimates of temperature at which an exothermic reaction initiates because the detected onset temperature is dependent upon the heating rate and because dynamic methods allow insufficient time for autocatalytic reactions to measurably affect the onset temperature. 5.4 RIT values determined under a series of isothermal test conditions may be plotted as their logarithm versus the reciprocal of the absolute temperature to produce a plot, the slope of which is proportional to the activation energy of the reaction as described in Test Methods E2070. 5.5 This test method may be used in research and development, manufacturing, process and quality control, and regulatory compliance. 5.6 This test method is similar to that for oxidation induction time (OIT) (for example, Specification D3350 and Test Methods D3895, D4565, D5483, D6186, and E1858) where the time to the oxidation reaction under isothermal test conditions is measured. The OIT test method measures the presence of antioxidant packages and is a relative measurement of a material’s resistance to oxidation.Scope 1.1 This test method describes the measurement of reaction induction time (RIT) of chemical materials that undergo exothermic reactions with an induction period. The techniques and apparatus described may be used for solids, liquids, or slurries of chemical substances. The temperature range covered by this test method is typically from ambient to 400 °C. This range may be extended depending upon the apparatus used. 1.2 The RIT is a relative index value, not an absolute thermodynamic property. As an index value, the RIT value may change depending upon experimental conditions. A comparison of RIT values may be made only for materials tested under similar conditions of apparatus, specimen size, and so forth. Furthermore, the RIT value may not predict behavior of large quantities of material. 1.3 The RIT shall not be used by itself to establish a safe operating temperature. It may be used in conjunction with other test methods (for example, Test Methods E487 and E537, and Guide E1981) as part of a hazard analysis of a particular operation. 1.4 This test method may be used for RIT values greater than 15 min (as relative imprecision increases at shorter periods). 1.5 This test method is used to study catalytic, autocatalytic, and accelerating reactions. These reactions depend upon time as well as temperature. Such reactions are often studied by fixing one experimental parameter (that is, time or temperature) and then measuring the other parameter (that is, temperature or time). This test method measures time to reaction onset detection under isothermal conditions. It is related to Test Method E487 that measures detected reaction onset temperature under constant time conditions 1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this test method. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
5935 - Connectors, Electrical (4357)
8455 - Badges and Insignia (3093)
8010 - Paints, Dopes, Varnishes, and Related Products (2046)
6515 - Medical and Surgical Instruments, Equipment, and Supplies (1907)
ISDF (1827)
4730 - Hose, Pipe, Tube, Lubrication, and Railing Fittings (1823)
ISDA (1776)
FACR (1647)
5960 - Electron Tubes and Associated Hardware (1630)
6145 - Wire and Cable, Electrical (1629)
6505 - Drugs and Biologicals (1343)
6625 - Electrical and Electronic Properties Measuring and Testing Instruments (1241)
6640 - Laboratory Equipment and Supplies (1187)
5120 - Hand Tools, Nonedged, Nonpowered (1124)
6810 - Chemicals (1114)
MISC (1045)
5930 - Switches (1012)
5306 - Bolts (996)
5340 - Hardware, Commercial (953)
8305 - Textile Fabrics (910)
5310 - Nuts and Washers (864)
5950 - Coils and Transformers (856)
8140 - Ammunition and Nuclear Ordnance Boxes, Packages and Special Containers (797)
6520 - Dental Instruments, Equipment, and Supplies (790)
ISDD (786)
5910 - Capacitors (783)
5305 - Screws (781)
9330 - Plastics Fabricated Materials (759)
5905 - Resistor (753)
6530 - Hospital Furniture, Equipment, Utensils, and Supplies (745)
5945 - Relays and Solenoids (733)
5961 - Semiconductor Devices and Associated Hardware (707)
6240 - Electric Lamps (662)
8415 - Clothing, Special Purpose (660)
5330 - Packing and Gasket Materials (583)
SESS (581)
ISDN (581)
5940 - Lugs, Terminals, and Terminal Strips (564)
8030 - Preservative and Sealing Compounds (554)
4720 - Hose and Flexible Tubing (552)
1375 - Demolition Materials (549)
6610 - Flight Instruments (540)
PACK (539)
8915 - Fruits and Vegetables (531)
1377 - Cartridge and Propellant Actuated Devices and Components (524)
Steel (908)
GUN (640)
銃 (621)
Demolition Materials (549)
Cartridge and Propellant Actuated Devices and Components (524)
Paint and Related Coating (456)
Fuzes and Primers (454)
Optical Sighting and Ranging Equipment (451)
Medical Device and Implant (427)
Building (414)
Petroleum (378)
Rockets, Rocket Ammunition and Rocket Components (368)
Nonferrous Metal and Nonferrous Alloy (367)
Ammunition, through 30mm (349)
Fire Control Computing Sights and Devices (338)
Aircraft Air Conditioning, Heating, and Pressurizing Equipment (334)
Parachutes; Aerial Pick Up, Delivery, Recovery Systems; and Cargo Tie Down Equipment (324)
Sports and Recreation (316)
Land Mines (276)
Nuclear Technology (274)
Consumer Product Evaluation (267)
Aircraft Hydraulic, Vacuum, and De-icing System Components (263)
Bulk Explosives (261)
Torpedos and Components, Inert (258)
Plastic Pipe (248)
Nondestructive Testing (246)
Miscellaneous Aircraft Accessories and Components (231)
Aerospace Material (225)
Geotechnical Engineering (217)
Miscellaneous Fire Control Equipment (216)
Ammunition, over 30mm up to 75mm (208)
Fire Control Radar Equipment, except Airborne (197)
Ammunition, 75mm through 125mm (192)
Bombs (192)
Copper (192)
Environmental Toxicology (187)
Analytical Chemistry (180)
Road and Paving (177)
Pyrotechnics (175)
Rubber (166)
Electrical and Magnetic Conductor (162)
Security System Pedestrian and Walkway Safety (157)
Military Chemical Agents (156)
Electronics (153)
Specialized Test and Handling Equipment, Nuclear Ordnance (150)

