Significance and Use

American National Standards Institute Inc.

5.1 The information in the examples of this guide are intended to be a starting point for determining the appropriate DCT criteria for a test method that measures a temperature-dependent property of a product within the scope of Committee D02. The criteria examples noted in this guide are based on the liquid-in-glass (LiG) thermometer design components, which are the bulb length, immersion depth, precision of measurement, thermometer position, and so forth. The parameters such as sensor length, immersion depth, and sheath diameter are especially critical when measuring the temperature of small static samples. This is due in part to the difference in thermal conductivity of a LiG vs. a DCT, however other aspects of the devices can contribute to unequal results. For example a DCT that is suitable for use in a stirred constant temperature bath will likely result in measurement errors when used to measure the temperature of a small static sample. This difference can be a degree or more when the sample temperature differs from room temperature by 40 °C or more using a 7 mm probe. This error is due to the difference in thermal conductivity and specific heat value of a DCT and LiG thermometer, however other aspects of the two different devices can contribute unequal results. One way to counter this is by reducing DCT sheath diameter, insulating the sheath above the immersion level, and using a probe that has a small immersion depth as determined by Practice D7962. For more guidance on selecting an appropriate DCT, see Guide E2877.

5.2 When replacing a LiG thermometer with a DCT noted in this guide and the test method does not list any DCT criteria, it is incumbent on the user to verify the suitability of the DCT they have selected. This can be done by comparing measurements made with the selected DCT to those of a LiG thermometer and following the test procedure. Comparative measurements are especially important when measuring the temperature of a small static sample where there is a large difference between sample and room temperature. Covering the DCT probe sheath except for the sensing portion with a glass, plastic, or tubing with a lower thermal conductivity can improve the agreement between LiG and DCT measurements.

Scope

1.1 The intent of this guide is to suggest an initial configuration and provide guidance when establishing the appropriate criteria needed for a DCT to correctly measure the temperature in a laboratory test method for products within the scope of this committee. This guide includes examples of the approximate digital contact thermometer (DCT) criteria that was found suitable for measuring temperature in the test methods utilized by Committee D02.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Go to ASTM D8164 at ASTM.org

Add your thoughts about the standard.

5935 - Connectors, Electrical (4357) 8455 - Badges and Insignia (3093) 8010 - Paints, Dopes, Varnishes, and Related Products (2046) 6515 - Medical and Surgical Instruments, Equipment, and Supplies (1907) ISDF (1827) 4730 - Hose, Pipe, Tube, Lubrication, and Railing Fittings (1823) ISDA (1776) FACR (1647) 5960 - Electron Tubes and Associated Hardware (1630) 6145 - Wire and Cable, Electrical (1629) 6505 - Drugs and Biologicals (1343) 6625 - Electrical and Electronic Properties Measuring and Testing Instruments (1241) 6640 - Laboratory Equipment and Supplies (1187) 5120 - Hand Tools, Nonedged, Nonpowered (1124) 6810 - Chemicals (1114) MISC (1045) 5930 - Switches (1012) 5306 - Bolts (996) 5340 - Hardware, Commercial (953) 8305 - Textile Fabrics (910) 5310 - Nuts and Washers (864) 5950 - Coils and Transformers (856) 8140 - Ammunition and Nuclear Ordnance Boxes, Packages and Special Containers (797) 6520 - Dental Instruments, Equipment, and Supplies (790) ISDD (786) 5910 - Capacitors (783) 5305 - Screws (781) 9330 - Plastics Fabricated Materials (759) 5905 - Resistor (753) 6530 - Hospital Furniture, Equipment, Utensils, and Supplies (745) 5945 - Relays and Solenoids (733) 5961 - Semiconductor Devices and Associated Hardware (707) 6240 - Electric Lamps (662) 8415 - Clothing, Special Purpose (660) 5330 - Packing and Gasket Materials (583) SESS (581) ISDN (581) 5940 - Lugs, Terminals, and Terminal Strips (564) 8030 - Preservative and Sealing Compounds (554) 4720 - Hose and Flexible Tubing (552) 1375 - Demolition Materials (549) 6610 - Flight Instruments (540) PACK (539) 8915 - Fruits and Vegetables (531) 1377 - Cartridge and Propellant Actuated Devices and Components (524)
Steel (908) GUN (640) (621) Demolition Materials (549) Cartridge and Propellant Actuated Devices and Components (524) Paint and Related Coating (456) Fuzes and Primers (454) Optical Sighting and Ranging Equipment (451) Medical Device and Implant (427) Building (414) Petroleum (378) Rockets, Rocket Ammunition and Rocket Components (368) Nonferrous Metal and Nonferrous Alloy (367) Ammunition, through 30mm (349) Fire Control Computing Sights and Devices (338) Aircraft Air Conditioning, Heating, and Pressurizing Equipment (334) Parachutes; Aerial Pick Up, Delivery, Recovery Systems; and Cargo Tie Down Equipment (324) Sports and Recreation (316) Land Mines (276) Nuclear Technology (274) Consumer Product Evaluation (267) Aircraft Hydraulic, Vacuum, and De-icing System Components (263) Bulk Explosives (261) Torpedos and Components, Inert (258) Plastic Pipe (248) Nondestructive Testing (246) Miscellaneous Aircraft Accessories and Components (231) Aerospace Material (225) Geotechnical Engineering (217) Miscellaneous Fire Control Equipment (216) Ammunition, over 30mm up to 75mm (208) Fire Control Radar Equipment, except Airborne (197) Ammunition, 75mm through 125mm (192) Bombs (192) Copper (192) Environmental Toxicology (187) Analytical Chemistry (180) Road and Paving (177) Pyrotechnics (175) Rubber (166) Electrical and Magnetic Conductor (162) Security System Pedestrian and Walkway Safety (157) Military Chemical Agents (156) Electronics (153) Specialized Test and Handling Equipment, Nuclear Ordnance (150)