Significance and Use 5.1 Conductivity measurements are typically made on samples of moderate to high ionic strength where contamination of open samples in routine laboratory handling is negligible. Under those conditions, standard temperature compensation using coefficients of 1 to 3 % of reading per degree Celsius over wide concentration ranges is appropriate. In contrast, this test method requires special considerations to reduce trace contamination and accommodates the high and variable temperature coefficients of pure water samples that can range as high as 7 % of reading per degree Celsius. In addition, measuring instrument design performance must be proven under high purity conditions. 5.2 This test method is applicable for detecting trace amounts of ionic contaminants in water. It is the primary means of monitoring the performance of demineralization and other high purity water treatment operations. It is also used to detect ionic contamination in boiler waters, microelectronics rinse waters, pharmaceutical process waters, etc., as well as to monitor and control the level of boiler and power plant cycle chemistry treatment chemicals. This test method supplements the basic measurement requirements for Test Methods D1125, D2186, and D4519. 5.3 At very low levels of alkaline contamination, for example, 0–1 μg/L NaOH, conductivity is suppressed, and can actually be slightly below the theoretical value for pure water. (1 and 2)4 Alkaline materials suppress the highly conductive hydrogen ion concentration while replacing it with less conductive sodium and hydroxide ions. This phenomenon is not an interference with conductivity or resistivity measurement itself but could give misleading indications of inferred water purity in this range if it is not recognized. Scope 1.1 This test method covers the determination of electrical conductivity and resistivity of high purity water samples below 10 μS/cm (above 0.1 Mohm-cm). It is applicable to both continuous and periodic measurements but in all cases, the water must be flowing in order to provide representative sampling. Static grab sampling cannot be used for such high purity water. Continuous measurements are made directly in pure water process lines, or in side stream sample lines to enable measurements on high temperature or high pressure samples, or both. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
5935 - Connectors, Electrical (4357)
8455 - Badges and Insignia (3093)
8010 - Paints, Dopes, Varnishes, and Related Products (2046)
6515 - Medical and Surgical Instruments, Equipment, and Supplies (1907)
ISDF (1827)
4730 - Hose, Pipe, Tube, Lubrication, and Railing Fittings (1823)
ISDA (1776)
FACR (1647)
5960 - Electron Tubes and Associated Hardware (1630)
6145 - Wire and Cable, Electrical (1629)
6505 - Drugs and Biologicals (1343)
6625 - Electrical and Electronic Properties Measuring and Testing Instruments (1241)
6640 - Laboratory Equipment and Supplies (1187)
5120 - Hand Tools, Nonedged, Nonpowered (1124)
6810 - Chemicals (1114)
MISC (1045)
5930 - Switches (1012)
5306 - Bolts (996)
5340 - Hardware, Commercial (953)
8305 - Textile Fabrics (910)
5310 - Nuts and Washers (864)
5950 - Coils and Transformers (856)
8140 - Ammunition and Nuclear Ordnance Boxes, Packages and Special Containers (797)
6520 - Dental Instruments, Equipment, and Supplies (790)
ISDD (786)
5910 - Capacitors (783)
5305 - Screws (781)
9330 - Plastics Fabricated Materials (759)
5905 - Resistor (753)
6530 - Hospital Furniture, Equipment, Utensils, and Supplies (745)
5945 - Relays and Solenoids (733)
5961 - Semiconductor Devices and Associated Hardware (707)
6240 - Electric Lamps (662)
8415 - Clothing, Special Purpose (660)
5330 - Packing and Gasket Materials (583)
SESS (581)
ISDN (581)
5940 - Lugs, Terminals, and Terminal Strips (564)
8030 - Preservative and Sealing Compounds (554)
4720 - Hose and Flexible Tubing (552)
1375 - Demolition Materials (549)
6610 - Flight Instruments (540)
PACK (539)
8915 - Fruits and Vegetables (531)
1377 - Cartridge and Propellant Actuated Devices and Components (524)
Steel (908)
GUN (640)
銃 (621)
Demolition Materials (549)
Cartridge and Propellant Actuated Devices and Components (524)
Paint and Related Coating (456)
Fuzes and Primers (454)
Optical Sighting and Ranging Equipment (451)
Medical Device and Implant (427)
Building (414)
Petroleum (378)
Rockets, Rocket Ammunition and Rocket Components (368)
Nonferrous Metal and Nonferrous Alloy (367)
Ammunition, through 30mm (349)
Fire Control Computing Sights and Devices (338)
Aircraft Air Conditioning, Heating, and Pressurizing Equipment (334)
Parachutes; Aerial Pick Up, Delivery, Recovery Systems; and Cargo Tie Down Equipment (324)
Sports and Recreation (316)
Land Mines (276)
Nuclear Technology (274)
Consumer Product Evaluation (267)
Aircraft Hydraulic, Vacuum, and De-icing System Components (263)
Bulk Explosives (261)
Torpedos and Components, Inert (258)
Plastic Pipe (248)
Nondestructive Testing (246)
Miscellaneous Aircraft Accessories and Components (231)
Aerospace Material (225)
Geotechnical Engineering (217)
Miscellaneous Fire Control Equipment (216)
Ammunition, over 30mm up to 75mm (208)
Fire Control Radar Equipment, except Airborne (197)
Ammunition, 75mm through 125mm (192)
Bombs (192)
Copper (192)
Environmental Toxicology (187)
Analytical Chemistry (180)
Road and Paving (177)
Pyrotechnics (175)
Rubber (166)
Electrical and Magnetic Conductor (162)
Security System Pedestrian and Walkway Safety (157)
Military Chemical Agents (156)
Electronics (153)
Specialized Test and Handling Equipment, Nuclear Ordnance (150)

