Significance and Use 4.1 This guide provides insight into the environmental conditions required for operation of laboratories or to aid in the design of new laboratories that perform carbon black testing activities using those test methods that are under D24’s jurisdiction. This guide does not supersede any specific requirements a laboratory may choose to establish. 4.2 This guide recommends the use of statistical x-charts to graphically monitor test data determined for the ASTM reference blacks for those test methods given in Section 2. All laboratories are encouraged to utilize statistical x-charts and ASTM reference blacks because this enables a comparison of testing precision within and between laboratories. The guide describes practices for the use of repeatability and reproducibility limits and x-charts. 4.3 In addition to the calibration of a test method by physicochemical means, a statistical method for achieving calibration of a test method is presented (that is, normalization). 4.4 Poor test precision can be the result of poor repeatability or poor reproducibility or both. Causes may include inadequate operator training, improperly maintained equipment or laboratory environment, variation in sample preparation or analysis techniques, the lack of calibration or standardization of instrumentation, worn-out apparatus, reagents that do not meet specifications, different sources of instrumentation or equipment, and material heterogeneity. The sum of all sources of testing error is unique for an individual laboratory. 4.5 Precision data for ASTM Reference Blacks are found in Tables 1-3. These include standard reference blacks (SRB’s) Series 8, HT and INR Iodine Standards. The HT or INR Iodine standards are recommended for monitoring iodine testing. (A) The iodine adsorption number of carbon black has been shown to decrease in value as the carbon black ages. Generally, the higher the surface area the faster the rate of change. Therefore, the target or mean values given in Table 1A may not be obtained due to this aging effect. Iodine Number testing should be monitored using HT or INR iodine standards and their reference values found in Table 2 and Table 3. See Section 10 for additional information. Note 1: Preferred precision values are bolded in Tables 1-3.Scope 1.1 This guide covers procedures for using the ASTM Standard Reference Blacks2 (SRBs) and the HT and INR Iodine Number Standards to continuously monitor the precision of those carbon black test methods for which reference values have been established. It also offers guidelines for troubleshooting various test methods. 1.2 This guide defines the environmental conditions that are required for laboratories that perform carbon black testing activities for those test methods under D24’s jurisdiction. 1.3 This guide establishes procedures for the use of x-charts to continuously monitor those tests listed in Section 2 for within-lab precision (repeatability) and between-lab accuracy (reproducibility). 1.4 This guide provides a statistical procedure for improving test reproducibility when a laboratory cannot physically calibrate its apparatus to obtain the reference values of the ASTM reference blacks, within the ranges given in this guide. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

American National Standards Institute Inc.

Go to ASTM D4821 at ASTM.org

Add your thoughts about the standard.

5935 - Connectors, Electrical (4357) 8455 - Badges and Insignia (3093) 8010 - Paints, Dopes, Varnishes, and Related Products (2046) 6515 - Medical and Surgical Instruments, Equipment, and Supplies (1907) ISDF (1827) 4730 - Hose, Pipe, Tube, Lubrication, and Railing Fittings (1823) ISDA (1776) FACR (1647) 5960 - Electron Tubes and Associated Hardware (1630) 6145 - Wire and Cable, Electrical (1629) 6505 - Drugs and Biologicals (1343) 6625 - Electrical and Electronic Properties Measuring and Testing Instruments (1241) 6640 - Laboratory Equipment and Supplies (1187) 5120 - Hand Tools, Nonedged, Nonpowered (1124) 6810 - Chemicals (1114) MISC (1045) 5930 - Switches (1012) 5306 - Bolts (996) 5340 - Hardware, Commercial (953) 8305 - Textile Fabrics (910) 5310 - Nuts and Washers (864) 5950 - Coils and Transformers (856) 8140 - Ammunition and Nuclear Ordnance Boxes, Packages and Special Containers (797) 6520 - Dental Instruments, Equipment, and Supplies (790) ISDD (786) 5910 - Capacitors (783) 5305 - Screws (781) 9330 - Plastics Fabricated Materials (759) 5905 - Resistor (753) 6530 - Hospital Furniture, Equipment, Utensils, and Supplies (745) 5945 - Relays and Solenoids (733) 5961 - Semiconductor Devices and Associated Hardware (707) 6240 - Electric Lamps (662) 8415 - Clothing, Special Purpose (660) 5330 - Packing and Gasket Materials (583) SESS (581) ISDN (581) 5940 - Lugs, Terminals, and Terminal Strips (564) 8030 - Preservative and Sealing Compounds (554) 4720 - Hose and Flexible Tubing (552) 1375 - Demolition Materials (549) 6610 - Flight Instruments (540) PACK (539) 8915 - Fruits and Vegetables (531) 1377 - Cartridge and Propellant Actuated Devices and Components (524)
Steel (908) GUN (640) (621) Demolition Materials (549) Cartridge and Propellant Actuated Devices and Components (524) Paint and Related Coating (456) Fuzes and Primers (454) Optical Sighting and Ranging Equipment (451) Medical Device and Implant (427) Building (414) Petroleum (378) Rockets, Rocket Ammunition and Rocket Components (368) Nonferrous Metal and Nonferrous Alloy (367) Ammunition, through 30mm (349) Fire Control Computing Sights and Devices (338) Aircraft Air Conditioning, Heating, and Pressurizing Equipment (334) Parachutes; Aerial Pick Up, Delivery, Recovery Systems; and Cargo Tie Down Equipment (324) Sports and Recreation (316) Land Mines (276) Nuclear Technology (274) Consumer Product Evaluation (267) Aircraft Hydraulic, Vacuum, and De-icing System Components (263) Bulk Explosives (261) Torpedos and Components, Inert (258) Plastic Pipe (248) Nondestructive Testing (246) Miscellaneous Aircraft Accessories and Components (231) Aerospace Material (225) Geotechnical Engineering (217) Miscellaneous Fire Control Equipment (216) Ammunition, over 30mm up to 75mm (208) Fire Control Radar Equipment, except Airborne (197) Ammunition, 75mm through 125mm (192) Bombs (192) Copper (192) Environmental Toxicology (187) Analytical Chemistry (180) Road and Paving (177) Pyrotechnics (175) Rubber (166) Electrical and Magnetic Conductor (162) Security System Pedestrian and Walkway Safety (157) Military Chemical Agents (156) Electronics (153) Specialized Test and Handling Equipment, Nuclear Ordnance (150)