Skip to content
規格マスター Logo規格マスター Logo
  • ホーム
  • FSC
  • AIA
    • AIA/NAS規格一覧
  • ASTM
    • ASTMアニュアルブック
  • ASME
    • ASMEボイラーコード
  • SAE
    • SAE規格一覧
  • お気に入り
  • お問い合わせ
  • 日本語
    • English

5945 - Relays and Solenoids規格の一覧

733の規格があります

American National Standards Institute Inc.

  • MIL-PRF-39016/26 – Relays, Electromagnetic, Established Reliability SPDT, Low Level to 1.0 Ampere (Sensitive, 40 Milliwatts) with Internal Diodes for Coil Transient Suppression and Polarity Reversal Protection

  • MIL-PRF-39016/27 – Relays, Electromagnetic, Established Reliability, SPDT, Low Level to 0.5 Ampere (Latching) with Internal Diodes for Coil Transient Suppression

  • MIL-PRF-39016/28 – Relays, Electromagnetic, Established Reliability, SPDT, Low Level to 0.5 Ampere (Latching) with Internal Diodes for Coil Transient Suppression and Polarity Reversal Protection

  • MIL-PRF-39016/23 – Relays, Electromagnetic, Established Reliability, SPDT, Low Level to 1.0 Ampere with Internal Diode for Coil Transient Suppression

  • MIL-PRF-39016/24 – Relays, Electromagnetic, Established Reliability, SPDT, Low Level to 1.0 Ampere with Internal Diodes for Coil Transient Suppression and Polarity Reversal Protection

  • MIL-PRF-39016/25 – Relays, Electromagnetic, Established Reliability, SPDT, Low Level to 1.0 Ampere (Sensitive, 40 Milliwatts) with Internal Diode for Coil Transient Suppression

  • MIL-PRF-39016/20 – Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere with Internal Diodes for Coil Transient Suppression and Polarity Reversal Protection

  • MIL-PRF-39016/21 – Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere (Sensitive, 60 Milliwatts) with Internal Diodes for Coil Transient Suppression and Polarity Reversal Protection

  • MIL-PRF-39016/22 – Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 2 Amperes (0.200-Inch Terminal Spacing) Coil Transient Suppressed

  • MIL-PRF-39016/17 – Relays, Electromagnetic, Established Reliability, DPDT, Low Level TO 1 Ampere Terminals 0.100-Inch Grid Pattern

  • MIL-PRF-39016/18 – Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1 Ampere with Internal Diode for Coil Transient Suppression, Terminals 0.100-Inch Grid Pattern

  • MIL-PRF-39016/19 – Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1 Ampere with Internal Diode for Coil Transient Suppression and Polarity Reversal Protection, Terminals 0.100-Inch Grid Pattern

  • MIL-PRF-39016/16 – Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere (Sensitive, 60 Milliwatts) with Internal Diode for Coil Transient Suppression

  • MIL-PRF-39016/14 – Relays, Electromagnetic, Established Reliability, 4PDT, Low Level To 2 Amperes (0.150-Inch Terminal Spacing)

  • MIL-PRF-39016/15 – Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere with Internal Diode for Coil Transient Suppression

  • MIL-PRF-39016/11 – Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere (Sensitive, 60 Milliwatts, Coil Operate Power at 25 Degrees C)

  • MIL-PRF-39016/12 – Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere (Latching)

  • MIL-PRF-39016/13 – Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 2 Amperes (0.150-Inch Terminal Spacing)

  • MIL-PRF-39016/8 – Relays, Electromagnetic, Established Reliability, SPDT, Low Level to 0.5 Ampere (Latching)

  • MIL-PRF-39016/9 – Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere

  • MIL-PRF-39016/10 – Relays, Electromagnetic, Established Reliability, SPDT, Low Level to 1.0 Ampere (Sensitive, 40 Milliwatts, Coil Operate Power at 25 Degrees C)

  • MIL-R-39016/5A – RELAY, ELECTROMAGNETIC, ESTABLISHED RELIABILITY (SUBMINIATURE, 2 PDT, LOW LEVEL, O TO 100 MILLIAMPERES) ( )USE MIL-R-39016/6(

  • MIL-PRF-39016/6 – Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 2 Amperes (0.200-Inch Terminal Spacing)

  • MIL-PRF-39016/7 – Relays, Electromagnetic, Established Reliability, SPDT, Low Level to 1 Ampere

  • MIL-R-39016/2 – RELAY, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, (MINIATURE, 2PDT, LOW LEVEL, 0 TO 100 MILLIAMPERES

  • MIL-R-39016/3 – RELAY, ELECTROMAGNETIC, ESTABLISHED RELIABILITY (MINIATURE, 2PDT, COMBINATION HIGH LEVEL AND LOW LEVEL, 0 TO 2 AMPERES)

  • MIL-R-39016/4 – RELAY, ELECTROMAGNETIC, ESTABLISHED RELIABILITY (SUBMINIATURE, 2 DPT, HIGH LEVEL, 2 AMPERES) (USE MIL-R-39016/6)

  • MIL-PRF-39016 – Relays, Electromagnetic, Established Reliability, General Specification for

  • MIL-R-39016 – RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, (MINIATURE, 2PDT, HIGH LEVEL, 2 AMPERES)

  • MIL-PRF-32140/1 – Relays, Electromagnetic, Radio Frequency, DC to 6 Gigahertz, Established Reliability, DPDT, Low Level to 1.0 Ampere, Hermetically Sealed (No S/S Document)

  • MIL-PRF-32085/2 – Relay, Electromagnetic, SPST, 270 Volt DC, 100 Ampere, Hermetically Sealed, Electrically Held or Magnetic Latching (No S/S Document)

  • MIL-PRF-32085/3 – Relay, Electromagnetic, SPST, 270 VOLT DC, 300 Ampere Hermetically Sealed, Transient Suppressed DC Coil (No S/S Document)

  • MIL-PRF-32140 – Relays, Electromagnetic, Radio Frequency, Established Reliability, General Specification for (No S/S Document)

  • MIL-R-28894/19 – RELAY, SOLID STATE, SENSORS, ESTABLISHED RELIABILITY, TYPE II (DC VOLTAGE SENSOR), CLASS C, SPST (NO), 250 MILLIAMPERES, HERMETICALLY SEALED (POTTED), PLUG-IN TERMINALS (NO S/S DOCUMENT)

  • MIL-PRF-32085 – Relays, Electromagnetic, 270 V DC, Established Reliability, General Specification for (No S/S Document)

  • MIL-PRF-32085/1 – Relay, Electromagnetic, SPST, 270 Volt DC, 120 Ampere, Hermetically Sealed, Transient Suppressed DC Coil (No S/S Document)

  • MIL-R-28894/16 – RELAYS, HYBRID, SENSORS, ESTABLISHED RELIABILITY, TYPE V (AC PHASE SEQUENCE SENSOR), CLASS B, 2PDT, LOW LEVEL TO 10 AMPERES, HERMETICALLY SEALED (POTTED (NO S/S DOCUMENT)

  • MIL-R-28894/17 – RELAYS, HYBRID, SENSORS, ESTABLISHED RELIABILITY, TYPE V (AC PHASE SEQUENCE SENSOR), CLASS B, 4PDT, LOW LEVEL TO 10 AMPERES, HERMETICALLY SEALED (POTTED) (NO S/S DOCUMENT)

  • MIL-R-28894/18 – RELAYS, SOLID STATE, SENSORS, ESTABLISHED RELIABILITY, TYPE II (DC UNDERVOLTAGE SENSORS), CLASS C, SPST (NO), HERMETICALLY SEALED (POTTED), PLUG-IN TERMINALS (NO S/S DOCUMENT)

  • MIL-R-28894/13 – RELAYS, HYBRID, SENSORS, ESTABLISHED RELIABILITY, TYPE III (AC OVERVOLTAGE SENSOR), CLASS B, 4PDT, LOW LEVEL TO 10 AMPERES, HERMETICALLY SEALED (POTTED) (NO S/S DOCUMENT)

  • MIL-R-28894/14 – RELAYS, HYBRID, SENSORS, ESTABLISHED RELIABILITY, TYPE IV (UNDER/OVER FREQUENCY SENSOR), CLASS B, 2PDT, LOW LEVEL TO 10 AMPERES, HERMETICALLY SEALED (POTTED) (NO S/S DOCUMENT)

  • MIL-R-28894/15 – RELAYS, HYBRID, SENSORS, ESTABLISHED RELIABILITY, TYPE IV (UNDER/OVER FREQUENCY SENSOR), CLASS B, 4PDT, LOW LEVEL TO 10 AMPERES, HERMETICALLY SEALED (POTTED) (NO S/S DOCUMENT)

  • MIL-R-28894/10 – RELAYS, HYBRID, SENSORS, ESTABLISHED RELIABILITY, TYPE III (AC UNDERVOLTAGE SENSOR), CLASS B, 2PDT, LOW LEVEL TO 10 AMPERES, HERMETICALLY SEALED (POTTED) (NO S/S DOCUMENT)

  • MIL-R-28894/11 – RELAYS, HYBRID, SENSORS, ESTABLISHED RELIABILITY, TYPE III (AC UNDERVOLTAGE SENSOR), CLASS B, 4PDT, LOW LEVEL TO 10 AMPERES, HERMETICALLY SEALED (POTTED) (NO S/S DOCUMENT)

  • MIL-R-28894/12 – RELAYS, HYBRID, SENSORS, ESTABLISHED RELIABILITY, TYPE III (AC OVERVOLTAGE SENSOR), CLASS B, 2PDT, LOW LEVEL TO 10 AMPERES, HERMETICALLY SEALED (POTTED) (NO S/S DOCUMENT)

  • MIL-R-28894/7 – RELAYS, HYBRID, SENSORS, ESTABLISHED RELIABILITY, TYPE I, CLASS B, (HYBRID AC POWER MONITORING SENSOR), 3PDT, LOW LEVEL TO 10 AMPERES, HERMETICALLY SEALED (POTTED), INVERTED MOUNT (NO S/S DOCUMENT)

  • MIL-R-28894/8 – RELAYS, HYBRID, SENSORS, ESTABLISHED RELIABILITY, TYPE II, CLASS B, (HYBRID DC VOLTAGE SENSOR), 2PDT, LOW LEVEL TO 10 AMPERES, HERMETICALLY SEALED (POTTED) (NO S/S DOCUMENT)

  • MIL-R-28894/9 – RELAYS, HYBRID, SENSORS, ESTABLISHED RELIABILITY, TYPE II, CLASS B, (HYBRID DC VOLTAGE SENSOR), 4PDT, LOW LEVEL TO 10 AMPERES, HERMETICALLY SEALED (POTTED) (NO S/S DOCUMENT)

  • MIL-R-28894/4 – RELAY, HYBRID, SENSORS, ESTABLISHED RELIABILITY, TYPE 1, CLASS B, (HYBRID AC POWER MONITORING SENSOR), 2PDT, LOW LEVEL TO 10 AMPERES, HERMETICALLY SEALED (POTTED), HORIZONTAL MOUNT WITH CONNECTOR TERMINATION (NO S/S DOCUMENT)

  • MIL-R-28894/5 – RELAYS, HYBRID, SENSORS, ESTABLISHED RELIABILITY, TYPE I, CLASS B, (HYBRID AC POWER MONITORING SENSOR), 3PDT, LOW LEVEL TO 10 AMPERES, HERMETICALLY SEALED (POTTED), VERTICAL MOUNT (NO S/S DOCUMENT)

  • MIL-R-28894/6 – RELAYS, HYBRID, SENSORS, ESTABLISHED RELIABILITY, TYPE I, CLASS B, (HYBRID AC POWER MONITORING SENSOR), 3PDT, LOW LEVEL TO 10 AMPERES, HERMETICALLY SEALED (POTTED), HORIZONTAL MOUNT (NO S/S DOCUMENT)

  • MIL-R-28894/1 – RELAYS, HYBRID, SENSORS, ESTABLISHED RELIABILITY, TYPE I, CLASS B, (HYBRID AC POWER MONITORING SENSOR), 2PDT, LOW LEVEL TO 10 AMPERES, HERMETICALLY SEALED (POTTED), VERTICAL MOUNT (NO S/S DOCUMENT)

  • MIL-R-28894/2 – RELAYS, HYBRID, SENSORS, ESTABLISHED RELIABILITY, TYPE I, CLASS B, (HYBRID AC POWER MONITORING SENSOR), 2PDT, LOW LEVEL TO 10 AMPERES, HERMETICALLY SEALED (POTTED), HORIZONTAL MOUNT (NO S/S DOCUMENT)

  • MIL-R-28894/3 – RELAY, HYBRID, SENSORS, ESTABLISHED RELIABILITY, TYPE I, CLASS B, (HYBRID AC POWER MONITORING SENSOR), 2PDT, LOW LEVEL TO 10 AMPERES, HERMETICALLY SEALED (POTTED), INVERTED MOUNT (NO S/S DOCUMENT)

  • MIL-PRF-28776/6 – Relays, Hybrid, Established Reliability, DPDT, Low Level to 1.0 Ampere Internal Mosfet drive with Zener Diode Gate Protection (Electromechanical Output) Diode Coil Suppression and Terminals with 0.100 Grid Lead Spacing

  • MIL-PRF-28776/7 – Relays, Hybrid, Established Reliability, DPDT, Low Level to 1.0 Ampere (Sensitive Coil Operate Power at 25 Deg. C), Internal Mosfet Driver with Zener Diode Gate Protection (Electromechanical Output) Diode Coil Suppression and Terminals with 0.100 Grid Lead Spacing

  • MIL-R-28894 – RELAYS, HYBRID OR SOLID STATE, SENSORS, ESTABLISHED RELIABILITY GENERAL SPECIFICATION FOR (NO S/S DOCUMENT)

  • MIL-PRF-28776/3 – Relays, Hybrid, Established Reliability, DPDT, Low-Level to 1.0 Ampere (Sensitive Coil Operate Power at 25 Degrees C) (Transistor Driven) (Electromechanical Output) with Diode Coil Suppression

  • MIL-PRF-28776/4 – Relays, Hybrid, Established Reliability, SPDT, Low-Level to 1.0 Ampere (Sensitive Coil Operate Power at 25 Degrees C) (Transistor Driven) (Electromechanical Output) with Diode Coil Suppression

  • MIL-PRF-28776/5 – Relays, Hybrid, Established Reliability, SPDT, Low-Level to 1.0 Ampere (Transistor Driven) (Electromechanical Output) with Diode Coil Suppression

  • MIL-R-28776 – RELAY, HYBRID, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 2 AMERES (0.150 INCH TERMINAL SPACING) (TRANSISTOR DRIVEN) (ELECTROMECHANICAL OUTPUT) (NO S/S DOCUMENT)

  • MIL-PRF-28776 – Relays, Hybrid, Established Reliability, General Specification for

  • MIL-PRF-28776/1 – Relays, Hybrid, Established Reliability, DPDT, Low-Level to 1.0 Ampere (Transistor Driven) (Electromechanical Output)

  • MIL-PRF-28750/10 – Relay, Solid-State, Sealed, Class I, Optically Isolated, Zero Voltage Turn-on, 25 Amperes, 250 V Maximum, 400 HZ, Power Switching, SPST (N.O.)

  • MIL-R-28769 – RELAY, ELECTRICAL, PHOTOSENSITIVE, (FOR CONTROL AND COMMUNICATION TYPE EQUIPMENT), GENERAL SPECIFICATION FOR

  • MIL-R-28769/1 – RELAY, ELECTRICAL, PHOTOSENSITIVE, SEALED, TYPE II, DOUBLE POLE, SINGLE THROW

  • MIL-R-28750/7 – Relay, Solid State, Hermetically Sealed, Isolated, 100 MA, 250 V DC, Signal Switching, SPST (N. O.)

  • MIL-PRF-28750/8 – Relay, Solid-State, Hermetically Sealed, Class II, Optically Isolated, 600 mA, 50 V dc, Signal Switching, SPST (N.O.)

  • MIL-PRF-28750/9 – Relay, Solid-State, Hermetically Sealed, Class II, Optically Isolated, Zero Voltage Turn-on, 1 Ampere (2 Amperes with Heat Sink), 400 HZ, Power Switching, SPST (N.O.)

  • MIL-R-28750/4 – RELAY, SOLID STATE, ENCAPSULATED, 1/4 AMPERE, 8 TO 32 VDC, ISOLATED, DPDT

  • MIL-R-28750/5 – Relay, Solid State, Hermetically Sealed, Isolated, Plus/Minus 50 MA, Plus/Minus 40 V, AC or DC, Analog Signal Switching, SPST (N.O.)

  • MIL-R-28750/6 – Relay, Solid State, Hermetically Sealed, Isolated, 250 MA, 40 V DC, Signal Switching, SPST (N. O.)

  • MIL-R-28750/1 – RELAY, SOLID STATE, ENCAPSULATED, 0 TO 60 VDC, 0 TO 1 AMPERE, DPDT

  • MIL-R-28750/2 – RELAY, SOLID STATE, ENCAPSULATED, 117 RMS, 2.5 AMPERE, DPDT

  • MIL-R-28750/3 – RELAY, SOLID STATE, ENCAPSULATED, 1 AMPERE, 8 TO 32 VDC, ISOLATED, SPST

  • MIL-R-27777/4 – RELAY, TELEGRAPH, PASSIVE, SOLID STATE RELAY, ELECTRONIC, SPECIAL PURPOSE (NO S/S DOCUMENT)

  • MIL-PRF-28750 – Relays, Solid State, General Specification for

  • MIL-R-27777/3 – RELAY, TELEGRAPH, PASSIVE, SOLID STATE, UNIVERSAL (202 BASE) (NO S/S DOCUMENT)

  • MIL-R-27777 – RELAY, TELEGRAPH, PASSIVE, SOLID-STATE GENERAL SPECIFICATION FOR (NO S/S DOCUMENT)

  • MIL-R-27777/1 – RELAY, TELEGRAPH, PASSIVE, SOLID STATE (OCTAL BASE) (NO S/S DOCUMENT)

  • MIL-R-27777/2 – RELAY, TELEGRAPH, PASSIVE, SOLID STATE (255 BASE) (NO S/S DOCUMENT)

  • MIL-F-26301 – Flasher, Solid State, Aircraft Navigational Light, General Specification for

  • MIL-F-26301/1 – Flasher, Aircraft Navigational Light, 115 Volts AC, 400 Hertz (No S/S Document)

  • MIL-R-26895 – RELAY, FIELD CONTROL, GENERATOR 28 VOLT DC, TYPE MD-1 (NO S/S DOCUMENT)

  • MIL-DTL-26126 – Relays, Electrical, Overvoltage, DC, General Specification for (No S/S Document)

  • MIL-R-26126 – RELAY, ELECTRICAL, OVERVOLTAGE, TYPE I, ELECTROMAGNETIC, SEALED (S/S BY MIL-R-26126/2 NOW MIL-DTL-26126/2)

  • MIL-DTL-26126/2 – Relay, Electrical, Overvoltage, Type II, Hybrid, Sealed (No S/S Document)

  • MIL-S-25259 – SWITCH, PROGRAMMER, CAM ACTUATING, TYPE MB&1

  • MIL-R-25850 – RELAY&SWITCH RE&222B-APR

  • MIL-F-25921 – Flasher, Position Light, Aircraft SDU-2-A, 28V DC (use MIL-F-26301)

  • MIL-R-24563 – Relay, Alternating Current, Power-Sensing

  • MIL-R-25018 – RELAYS, MINIATURIZED, HERMETICALLY SEALED, AIRBORNE EQUIPMENT, GENERAL SPECIFICATION FOR (SUPERSEDES MML&R&5757 IN PART)

  • MIL-R-25078 – RELAY, GENERATOR OVER VOLTAGE PROTECTION, TYPE MB-1

  • MIL-R-22527 – RELAY, ARMATURE (NO S/S DOCUMENT)

  • MIL-R-23056 – RELAY ASSEMBLY, AIRPORT SERIES LIGHTING, 6.6 AMPERES (NO S/S DOCUMENT)

  • MIL-C-24010 – Contactor, Electric Power Line, Aircraft, General Specification for (No S/S Document)

  • MIL-R-21093/7 – RELAY, ARMATURE, GENERAL PURPOSE, TYPE RA1E01MDO01

  • MIL-R-21093/8 – RELAYS, ARMATURE, GENERAL PURPOSE, TYPE RYA1E01MEO01

  • MIL-R-21413 – RELAY, THERMAL, MARK 24 MOD 0 (NO S/S DOCUMENT)

  • MIL-R-21093/4 – RELAY, ARMATURE, GENERAL PURPOSE, TYPE RYA1E01MAO01

前へ456次へ
規格マスター Logo規格マスター Logo

規格マスターは工業規格を使用するエンジニアのための情報源・コミュニティサイトになることを目標にしています。

技術仕様書や規格に関する情報や知見を探すことは膨大な時間や労力を要します。

私たちは、エンジニアがさまざまな仕様や規格について議論し、その知識を共有するためのウェブサイトとして開発しています。

  • AIA/NAS
  • ASTM
  • AWS

  • ISO

  • SAE

4720 - Hose and Flexible Tubing (552) 4730 - Hose, Pipe, Tube, Lubrication, and Railing Fittings (1823) 5120 - Hand Tools, Nonedged, Nonpowered (1124) 5305 - Screws (781) 5306 - Bolts (996) 5310 - Nuts and Washers (864) 5330 - Packing and Gasket Materials (583) 5340 - Hardware, Commercial (953) 5820 - Radio and Television Communication Equipment, Except Airborne (503) 5905 - Resistor (753) 5910 - Capacitors (783) 5920 - Fuses, Arrestors, Absorbers, and Protectors (512) 5930 - Switches (1012) 5935 - Connectors, Electrical (4357) 5940 - Lugs, Terminals, and Terminal Strips (564) 5945 - Relays and Solenoids (733) 5950 - Coils and Transformers (856) 5960 - Electron Tubes and Associated Hardware (1630) 5961 - Semiconductor Devices and Associated Hardware (707) 6145 - Wire and Cable, Electrical (1629) 6240 - Electric Lamps (662) 6505 - Drugs and Biologicals (1343) 6515 - Medical and Surgical Instruments, Equipment, and Supplies (1907) 6520 - Dental Instruments, Equipment, and Supplies (790) 6530 - Hospital Furniture, Equipment, Utensils, and Supplies (745) 6610 - Flight Instruments (540) 6625 - Electrical and Electronic Properties Measuring and Testing Instruments (1241) 6640 - Laboratory Equipment and Supplies (1187) 6810 - Chemicals (1114) 8010 - Paints, Dopes, Varnishes, and Related Products (2046) 8030 - Preservative and Sealing Compounds (554) 8140 - Ammunition and Nuclear Ordnance Boxes, Packages and Special Containers (797) 8305 - Textile Fabrics (910) 8415 - Clothing, Special Purpose (660) 8455 - Badges and Insignia (3093) 8915 - Fruits and Vegetables (531) 9330 - Plastics Fabricated Materials (759) FACR (1647) ISDA (1776) ISDD (786) ISDF (1827) ISDN (581) MISC (1045) PACK (539) SESS (581)

© All rights reserved. • kikakumaster.com

Page load link
Notice. KikakuMaster uses cookies to provide necessary website functionality, improve your experience and analyze our traffic. By using our website, you agree to our Terms of Use, our Privacy Policy . Settings Ok Reject

Essential cookies

Essential cookies are crucial to your experience of a website, enabling core features like user logins, account management, shopping carts, and payment processing. We use essential cookies to enable certain functions on our website.
Go to Top