Significance and Use 5.1 Liposomes are vesicles of nanoscale dimensions, composed of lipid bilayers, which are used for various diagnostic and therapeutic applications (9). The growing interest in liposomal formulations in the delivery of various drugs, antisense oligonucleotides, cloned genes, or recombinant proteins by the biopharmaceutical industry, warrants QC and thorough characterization of the constituent lipids. Lipid structure, composition, and concentration are key attributes in determining the quality and efficacy of a liposomal drug product as they influence the stability of liposomes, drug loading, release kinetics, biodistribution, and pharmacokinetic properties (9). Cholesterol modulates the lipid membrane fluidity, elasticity, and permeability; hence, it plays a key role in controlled drug release and increased stability of the liposome (10). 5.2 This test method provides a rapid and reliable protocol for the determination of cholesterol, DSPE-PEG 2000, and HSPC in liposomal formulations using UHPLC-TQMS. Assessment of the stability of the analytes in terms of their degradation profiles is not included in this test method (11). This test method will benefit the biopharmaceutical industry in ascertaining quality assessment of liposomal formulations and monitoring batch-to-batch consistency for large-scale production, thereby facilitating safe and efficient drug development and regulatory review. 5.3 UHPLC-MS/MS measurements are analytically more sensitive and specific for lipid analysis compared to other contemporary techniques using universal detectors, such as a charged aerosol or an evaporative light-scattering detector. For liposomes, MS/MS has further advantages over ultraviolet detectors, as lipids lack chromophores for detection. In this test method, TQMS has been used as the MS/MS technique of choice because of its high selectivity, sensitivity, S/N, accuracy, and broad linear range of quantitation, thereby allowing reproducible quantitation of the analytes, especially at low concentrations. 5.4 According to the Current Good Manufacturing Practice regulations [21 CFR 211.194(a)(2)], users are required to verify the suitability of the test method under actual conditions of use. Validation should assess the suitability of the test method for the product matrix, recovery of the analytes from the product matrix, suitability of chromatographic conditions and column, appropriateness of the detector signal response, specificity, limit of detection and quantitation, accuracy, and precision. The user may need to optimize method parameters and cross validate if a different chromatography column, ionization method, or mass analyzer is used.Scope 1.1 This test method describes the determination of lipid components in liposomal formulations, which includes sample solubilization in methanol followed by separation of the analytes using ultra-high-performance liquid chromatography (UHPLC) and detection with tandem mass-spectrometry (MS/MS). This test method adheres to multiple reaction monitoring (MRM) mass spectrometry on a triple quadrupole mass spectrometer (TQMS). 1.2 This test method is specific for liposomal formulations containing cholesterol, 1,2- distearoyl-sn-glycero-3-phosphoethanolamine-N-[methoxy (polyethylene glycol)-2000] (DSPE- PEG 2000), and hydrogenated (soy) L-α-phosphatidylcholine (HSPC). 1.3 This test method is applicable to report the absolute concentrations of cholesterol, DSPE-PEG 2000, and HSPC and their ratio (DSPE-PEG 2000: HSPC: cholesterol) in liposomal formulations. Assessment of the stability of the analytes in terms of their degradation as a result of oxidation or hydrolysis is beyond the scope of this test method. 1.4 This test method includes calibration and standardization, sample preparation, UHPLC-TQMS instrumentation, potential interferences, method validation with acceptance criteria, sample analysis, and data reporting. 1.5 The detection limits for cholesterol, DSPE-PEG 2000, and HSPC using this test method are 5.3, 0.5, and 0.5 ng/g, respectively. In addition, the quantitation limits for cholesterol, DSPE-PEG 2000, and HSPC are 10.6, 0.8, and 0.5 ng/g, respectively. 1.6 This test method is intended for concentration ranges of 8-1600 ng/g for cholesterol, and of 2-400 ng/g for DSPE-PEG 2000 and HSPC. 1.7 All observed and calculated values shall conform to the guidelines for significant digits and rounding as established in Practice D6026. 1.8 Units—The values stated in SI units are to be regarded as the standard. Where appropriate, c.g.s units in addition to SI units are included in this standard. 1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.10 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

American National Standards Institute Inc.

Go to ASTM E3324 at ASTM.org

Add your thoughts about the standard.

1375 - Demolition Materials (549) 1377 - Cartridge and Propellant Actuated Devices and Components (524) 4720 - Hose and Flexible Tubing (552) 4730 - Hose, Pipe, Tube, Lubrication, and Railing Fittings (1823) 5120 - Hand Tools, Nonedged, Nonpowered (1124) 5305 - Screws (781) 5306 - Bolts (996) 5310 - Nuts and Washers (864) 5330 - Packing and Gasket Materials (583) 5340 - Hardware, Commercial (953) 5905 - Resistor (753) 5910 - Capacitors (783) 5930 - Switches (1012) 5935 - Connectors, Electrical (4357) 5940 - Lugs, Terminals, and Terminal Strips (564) 5945 - Relays and Solenoids (733) 5950 - Coils and Transformers (856) 5960 - Electron Tubes and Associated Hardware (1630) 5961 - Semiconductor Devices and Associated Hardware (707) 6145 - Wire and Cable, Electrical (1629) 6240 - Electric Lamps (662) 6505 - Drugs and Biologicals (1343) 6515 - Medical and Surgical Instruments, Equipment, and Supplies (1907) 6520 - Dental Instruments, Equipment, and Supplies (790) 6530 - Hospital Furniture, Equipment, Utensils, and Supplies (745) 6610 - Flight Instruments (540) 6625 - Electrical and Electronic Properties Measuring and Testing Instruments (1241) 6640 - Laboratory Equipment and Supplies (1187) 6810 - Chemicals (1114) 8010 - Paints, Dopes, Varnishes, and Related Products (2046) 8030 - Preservative and Sealing Compounds (554) 8140 - Ammunition and Nuclear Ordnance Boxes, Packages and Special Containers (797) 8305 - Textile Fabrics (910) 8415 - Clothing, Special Purpose (660) 8455 - Badges and Insignia (3093) 8915 - Fruits and Vegetables (531) 9330 - Plastics Fabricated Materials (759) FACR (1647) ISDA (1776) ISDD (786) ISDF (1827) ISDN (581) MISC (1045) PACK (539) SESS (581)
Aerospace Material (225) Aircraft Air Conditioning, Heating, and Pressurizing Equipment (334) Aircraft Hydraulic, Vacuum, and De-icing System Components (263) Ammunition, 75mm through 125mm (192) Ammunition, over 30mm up to 75mm (208) Ammunition, through 30mm (349) Analytical Chemistry (180) Bombs (192) Building (414) Bulk Explosives (261) Cartridge and Propellant Actuated Devices and Components (524) Consumer Product Evaluation (267) Copper (192) Demolition Materials (549) Electrical and Magnetic Conductor (162) Electronics (153) Environmental Toxicology (187) Fire Control Computing Sights and Devices (338) Fire Control Radar Equipment, except Airborne (197) Fuzes and Primers (454) Geotechnical Engineering (217) GUN (640) Land Mines (276) Medical Device and Implant (427) Military Chemical Agents (156) Miscellaneous Aircraft Accessories and Components (231) Miscellaneous Fire Control Equipment (216) Nondestructive Testing (246) Nonferrous Metal and Nonferrous Alloy (367) Nuclear Technology (274) Optical Sighting and Ranging Equipment (451) Paint and Related Coating (456) Parachutes; Aerial Pick Up, Delivery, Recovery Systems; and Cargo Tie Down Equipment (324) Petroleum (378) Plastic Pipe (248) Pyrotechnics (175) Road and Paving (177) Rockets, Rocket Ammunition and Rocket Components (368) Rubber (166) Security System Pedestrian and Walkway Safety (157) Specialized Test and Handling Equipment, Nuclear Ordnance (150) Sports and Recreation (316) Steel (908) Torpedos and Components, Inert (258) (621)