Significance and Use 5.1 This test method is considered a rapid method when compared to other classical methods for the determination of 241Am in aqueous solutions. During the method validation of this method, a test batch of fourteen test samples plus quality control samples was chemically processed in ~7.5 hours. Additional time for counting the samples depends on the measurement quality objectives. 5.2 This test method is specific for Americium-241 (241Am) in drinking water and other aqueous samples. However, if any isotopes of curium are present in the sample, they will be carried with americium during the analytical separation process and will be observed in the final alpha spectrum. 5.3 This test method is capable of achieving a required method uncertainty for 241Am of 0.070 Bq/L at an analytical action level of 0.555 Bq/L. This test method is capable of achieving a required relative method uncertainty, φMR, 13 % above 0.555 Bq/L. This test method is capable of achieving a “required” minimum detectable concentration (MDC) of 0.055 Bq/L. 5.4 To attain these stated measurement quality objectives (MQOs), a sample volume of approximately 200 mL and count time of at least 1 to 3 hours are recommended. The sample turnaround time and throughput may vary based on additional project MQOs, the time for analysis of the final counting form, and initial sample volume. This test method should be validated before use following the protocols provided in Method Validation Guide for Qualifying Methods Used by Radiological Laboratories Participating in Incident Response Activities.4 5.5 This test method is intended to be used for water samples that are similar in composition to drinking water. This method was evaluated following the guidance presented for “Level E Method Validation: Adapted or Newly Developed Methods, Including Rapid Methods” in Method Validation Guide for Qualifying Methods Used by Radiological Laboratories Participating in Incident Response Activities and Chapter 6 of MARLAP, 2004.3 Multi-radionuclide analysis using sequential separation may be possible using this test method in conjunction with other rapid methods.Scope 1.1 This test method is specifically for Americium-241 (241Am) in drinking water and other aqueous samples. However, if any isotopes of curium are present in the sample, they will be carried with americium during the analytical separation process and will be observed in the final alpha spectrum. The presence of 243Am in the water sample will bias the results obtained by this test method. 1.2 This test method is applicable to samples in which radioactive contamination is from either known or unknown origins. If any filtration of the sample is performed before starting the analysis, those solids should be analyzed separately. The results from the analysis of these solids should be reported separately (as a suspended activity concentration for the water volume filtered) but identified with the filtrate results. 1.3 This test method is applicable to the determination of soluble 241Am. This test method is not applicable to the determination of 241Am in highly insoluble particulate matter possibly present in water samples contaminated as a result of a radiological dispersal device (RDD) event. 1.4 This test method uses rapid radiochemical separation techniques for determining americium in water samples following a radiological or nuclear incident. Although, with this test method, concentrations of 241Am on the same order of magnitude as methods used for the Safe Drinking Water Act (SDWA) can be detected, this test method is not a substitute for SDWA-approved methods for 241Am. 1.5 Units—The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

American National Standards Institute Inc.

Go to ASTM D7939 at ASTM.org

Add your thoughts about the standard.

1375 - Demolition Materials (549) 1377 - Cartridge and Propellant Actuated Devices and Components (524) 4720 - Hose and Flexible Tubing (552) 4730 - Hose, Pipe, Tube, Lubrication, and Railing Fittings (1823) 5120 - Hand Tools, Nonedged, Nonpowered (1124) 5305 - Screws (781) 5306 - Bolts (996) 5310 - Nuts and Washers (864) 5330 - Packing and Gasket Materials (583) 5340 - Hardware, Commercial (953) 5905 - Resistor (753) 5910 - Capacitors (783) 5930 - Switches (1012) 5935 - Connectors, Electrical (4357) 5940 - Lugs, Terminals, and Terminal Strips (564) 5945 - Relays and Solenoids (733) 5950 - Coils and Transformers (856) 5960 - Electron Tubes and Associated Hardware (1630) 5961 - Semiconductor Devices and Associated Hardware (707) 6145 - Wire and Cable, Electrical (1629) 6240 - Electric Lamps (662) 6505 - Drugs and Biologicals (1343) 6515 - Medical and Surgical Instruments, Equipment, and Supplies (1907) 6520 - Dental Instruments, Equipment, and Supplies (790) 6530 - Hospital Furniture, Equipment, Utensils, and Supplies (745) 6610 - Flight Instruments (540) 6625 - Electrical and Electronic Properties Measuring and Testing Instruments (1241) 6640 - Laboratory Equipment and Supplies (1187) 6810 - Chemicals (1114) 8010 - Paints, Dopes, Varnishes, and Related Products (2046) 8030 - Preservative and Sealing Compounds (554) 8140 - Ammunition and Nuclear Ordnance Boxes, Packages and Special Containers (797) 8305 - Textile Fabrics (910) 8415 - Clothing, Special Purpose (660) 8455 - Badges and Insignia (3093) 8915 - Fruits and Vegetables (531) 9330 - Plastics Fabricated Materials (759) FACR (1647) ISDA (1776) ISDD (786) ISDF (1827) ISDN (581) MISC (1045) PACK (539) SESS (581)
Aerospace Material (225) Aircraft Air Conditioning, Heating, and Pressurizing Equipment (334) Aircraft Hydraulic, Vacuum, and De-icing System Components (263) Ammunition, 75mm through 125mm (192) Ammunition, over 30mm up to 75mm (208) Ammunition, through 30mm (349) Analytical Chemistry (180) Bombs (192) Building (414) Bulk Explosives (261) Cartridge and Propellant Actuated Devices and Components (524) Consumer Product Evaluation (267) Copper (192) Demolition Materials (549) Electrical and Magnetic Conductor (162) Electronics (153) Environmental Toxicology (187) Fire Control Computing Sights and Devices (338) Fire Control Radar Equipment, except Airborne (197) Fuzes and Primers (454) Geotechnical Engineering (217) GUN (640) Land Mines (276) Medical Device and Implant (427) Military Chemical Agents (156) Miscellaneous Aircraft Accessories and Components (231) Miscellaneous Fire Control Equipment (216) Nondestructive Testing (246) Nonferrous Metal and Nonferrous Alloy (367) Nuclear Technology (274) Optical Sighting and Ranging Equipment (451) Paint and Related Coating (456) Parachutes; Aerial Pick Up, Delivery, Recovery Systems; and Cargo Tie Down Equipment (324) Petroleum (378) Plastic Pipe (248) Pyrotechnics (175) Road and Paving (177) Rockets, Rocket Ammunition and Rocket Components (368) Rubber (166) Security System Pedestrian and Walkway Safety (157) Specialized Test and Handling Equipment, Nuclear Ordnance (150) Sports and Recreation (316) Steel (908) Torpedos and Components, Inert (258) (621)